Commercial Dedicated Equipment Circuits in Santa Clarita

From Valencia Commerce Center to Old Town Newhall, Santa Clarita businesses rely on steady, compliant power to keep operations running. Shaffer Construction, Inc. designs and installs dedicated equipment circuits that match the exact power needs of your refrigeration, servers, kitchen equipment, medical devices, and manufacturing tools—without nuisance trips or guesswork. We understand the unique mix of tilt-up warehouses, medical suites near Henry Mayo Newhall Hospital, bustling restaurants around Westfield Valencia Town Center, and offices along Tourney Road. Our C-10 licensed electricians handle assessment, engineering, permitting, installation, and testing end-to-end. Whether you're adding a new espresso machine in Newhall or a row of server racks near College of the Canyons, we deliver clean, dedicated power with minimal downtime and clear documentation.

Licensed & Insured
A, B & C10 Contractor
25+ Years
Experience in LA
1000+ Projects
Successfully Completed

Our Work

Tesla Supercharger station with solar canopy installation by Shaffer Construction electrical contractorsCommercial EV charging infrastructure with electrical panels and utility meters installed by licensed electriciansTesla Powerwall battery storage system professionally installed on residential home exterior

Benefits

Built for Future Growth

We future-proof your circuits with capacity planning and smart infrastructure. Our designs include space-capable panels, spare conduit or pull strings for later expansion, and metering options to monitor usage. For sensitive equipment, we deploy isolated ground receptacles, transient voltage surge suppression (TVSS), and power-quality devices. We design for 120/208V and 277/480V three-phase systems common in Santa Clarita’s commercial buildings, ensuring easy scalability as you add machines, racks, or refrigeration lines.

Expert Permits and Compliance

Shaffer Construction manages the entire permitting process with the City of Santa Clarita Building and Safety Division. We prepare panel schedules, one-line diagrams, and load calculations (per CEC Article 220), submit plans, and meet inspectors on site. Our installations follow the California Electrical Code, Title 24 requirements where applicable, NFPA 70E safe work practices, and UL-listed methods. You get full compliance documentation and as-built drawings for your records and landlord requirements.

Unmatched Quality and Reliability

We specify copper THHN/THWN-2 conductors in EMT, rigid, or PVC where appropriate, and we size conductors for voltage drop and temperature derating. Breakers are selected to match equipment inrush and protection needs (standard, GFCI, HACR, or motor-rated). Terminations are torqued to manufacturer specs and verified, and penetrations are firestopped with tested systems. We label circuits clearly, balance phases for three-phase panels, and perform thermal and function tests to verify reliability under load.

Personalized Design Plans

Every project starts with a site assessment and review of equipment nameplate data and cut sheets. We coordinate with your vendors to confirm amperage, voltage, phase, receptacle type (e.g., NEMA 5-20R, L6-30R, 14-50R), and any hardwire/disconnect requirements. Our team produces circuit routing plans that minimize downtime and preserve aesthetics, updates panel schedules, and prepares a concise one-line. You receive a clear scope, timeline, and installation plan that fits your business operations.

What We Offer

Dedicated circuits for commercial refrigeration, walk-in coolers, and freezers with lockable disconnects
Isolated ground circuits and surge protection for server rooms and network racks
Hardwired connections and HACR-rated breakers for rooftop package HVAC units
Dedicated 20A and 30A circuits for espresso machines, ovens, and line equipment in restaurants
NEMA L6-30R and L5-30R receptacles for copiers, plotters, and production printers
Dedicated circuits for dental chairs, air compressors, and vacuum pumps in medical/dental suites
Power to CNC machines, drill presses, lathes, and small manufacturing equipment
Level 2 EV fleet charging circuits and panel capacity planning
Dedicated pump and motor circuits with appropriate overload protection
Receptacles and circuits for hair dryers, tanning beds, and salon equipment
Under-counter ice machine and prep table circuits with GFCI where required
Commercial water heater circuits and local disconnects
POS system power with cable management and clean grounding
Dedicated signage and menu board circuits, timer integration as needed
Subpanel additions and feeder upgrades to support new dedicated loads

Frequently Asked Questions

Do I need a dedicated circuit for my commercial refrigeration in Santa Clarita?+

Yes. Most commercial coolers, freezers, and ice machines require a dedicated circuit sized to the nameplate amperage with proper overcurrent protection. Dedicated circuits reduce nuisance trips and protect inventory. We confirm voltage (often 120V or 208/240V), amp draw, and whether a hardwired disconnect or a specific NEMA receptacle is required, then handle permits with the City of Santa Clarita.

Can you install circuits after hours to avoid downtime?+

Absolutely. We regularly schedule night or weekend installations for restaurants, offices, and retail spaces. We can pre-stage conduit during off-peak times, then perform panel shutdowns and tie-ins when you’re closed. We coordinate inspections accordingly so your operations remain uninterrupted.

How long does permitting take in Santa Clarita for new circuits?+

Most dedicated circuit projects require a simple electrical permit. The City of Santa Clarita Building and Safety Division typically issues permits in 1–3 weeks. We prepare load calcs, one-lines, and panel schedules, submit on your behalf, and align inspections with your availability to keep the project moving.

What voltage and receptacle types are common in local commercial buildings?+

Many Santa Clarita buildings have 120/208V three-phase service; some larger facilities use 277/480V. Common receptacles include 5-20R for general equipment and L6-30R or L5-30R for higher loads. We verify your service and equipment nameplate to select the correct breaker, conductor size, and receptacle or hardwire method.

What if my panel is full or undersized for new equipment?+

We evaluate options like tandem breakers (if listed), relocating circuits, adding a subpanel, or upgrading the main panel or feeders. We also perform load calculations and consider future loads. If an upgrade is necessary, we coordinate with your landlord and SCE to plan shutdowns and minimize business impact.

Can you provide isolated grounds or surge protection for sensitive electronics?+

Yes. For server rooms, POS, and AV systems, we can install isolated ground receptacles, dedicated grounding conductors, and panel-level surge protection. We verify grounding electrode bonding and provide clean, labeled circuits that help protect sensitive electronics from transients and interference.

Ready to Get Started?

Contact us today for a free consultation and quote on your electrical project!

Contact Us